Smoke Exempt Requirements
eVo 7 Inset - Ignition
The procedure adopted for ignition is to build a bed of embers in stages with the objective of
warming the stove as quickly as possible. Firstly, a double handful of kindling (equivalent to the
weight of about 1 kg) should be lit with chemical fire-lighters. The primary air and secondary air
controls must be fully open at this stage. The fire door needs to be pushed against the latch but
not closed, leaving a gap of a few millimetres. After about 8 minutes, with the fire bed dying back, 3
half sized logs (total weight about 1.2 kg) should be added with the air controls unaltered. After
approximately a further 2 minutes, when these logs are well alight the door and primary air supply
can be closed. Then allow the fire to burn down to embers with the secondary air supply
maintained at maximum, at which point the ignition sequence is deemed to have ended.
Evo 7 Inset - Refuelling
The refuelling procedure adopted for the PD6434 tests allows the newly charged fuel to burn with
the door set on the latch but not closed, the primary control set fully open for 1 2 minutes and the
secondary air set in the required positions necessary for the various outputs. After 1 2 minutes,
with the logs burning well, the door and primary air supply needs to be closed but the secondary air
control position can remained unaltered. The tertiary air supply is maintained with its permanent
opening throughout.
Evo 4 Inset – Ignition
The procedure adopted for ignition is to build a bed in stages and to warm the body of the
appliance and the chimney as quickly as practicable. Firstly kindling, weighing approximately 1 kg
will need to be lit (using a chemical fire-lighter is recommended) with the air control fully open. The
door must be pushed against the appliance but then left ajar. After about 10 minutes, when the fire
from the kindling is beginning to die back, two small logs can be added. When these are alight and
fully blackened, the door can be closed. This, typically, takes approximately a further five minutes.
When the fire is again beginning to die back, a full load of two logs, weighing about 1.3 1.4 kg,
can be added: typically this takes 20 – 25 minutes from the start of the ignition sequence. The
Secondary air control must be maintained in its fully open position for the remainder of the ignition
sequence. Once the fuel has blackened the fire can then be allowed to burn down to a suitable
condition at a preferable air slider position. For start of further re fuelling apply sequence in the
previous 2 sentences.
Evo 4 Inset – Refuelling
There is a requirement for the door to be left ajar for 3 minutes immediately after refuelling. This is
to ensure that flames are well established on the newly charged logs and that they become fully
blackened. Additionally, for medium and low output burning, the Secondary air control must be
Maintained at 100% open for the first 3 minutes after refuelling at which time it is possible to adjust
to the required settings as identified above. The primary air intake is not required at this stage.