Chimney Requirements
This appliance must not be fitted into a chimney serving another heating appliance. It is
most important that there is no obstruction in the flue or chimney. Please ensure that any
existing chimney is clear of obstruction and swept clean immediately before installation of
the new stove. If the chimney has been used for an open fire it is recommended that it be
swept for a second time having been used for a month following installation.
A flue draught minimum of 12 Pascals to a maximum 16 Pascals is required for
satisfactory appliance performance. A properly built masonry or factory constructed
chimney (with a minimum vertical height of 5 metres) should ensure a consistent draught
(draw).
The flue draught should be checked under fire at high output. If you have any doubts about
the suitability of your chimney, consult your local dealer/stockist or engineer. If your flue
draft is below the minimum recommendation then it may be necessary to increase the
vertical chimney height, add additional flue insulation or possibly add a special cowl to the
top of the chimney (e.g. anti down draft cowl to eliminate wind induced down draft).
The outlet from the chimney should be above the roof of the building in accordance with
the provisions of Building Regulations Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other
faults which might allow fumes into the house. Older properties, especially, may have
chimney faults or the cross section may be too large i.e. more than 230 mm x 230 mm.
Remedial action should be taken, if required, seeking expert advice, if necessary. If it is
found necessary to line the chimney then a flue liner suitable for solid fuel must be used in
accordance with Building Regulations Approved Document J.
If there is no existing chimney then either a prefabricated block chimney in accordance
with Building Regulations Approved Document J or a twin walled insulated stainless steel
flue to BS 4543 can be used. These chimneys must be fitted in accordance with the
manufacturer’s instructions and Building Regulations.
The stoves flue spigot is designed to accept a 6” / 150mm diameter pipe, it is possible to
connect the flexible liner to the spigot using self tapping screws. If no flexible liner is
present, the stove will need to be securely sealed into the fireplace opening (see section
“Assembly” for further information).
For sweeping purposes it is possible to sweep through the appliance, however you will
need to remove the internal baffle(s) to do so (see section “Assembly” for further
information).